CheckCIF-PLAT193-203
PLAT193 Type_1 Test for consistency of cell & diffraction temperatures
The reported _cell_measurement_temperature deviates from the reported _diffrn_ambient_temperature values.
所報(bào)告的_cell_measurement_temperature值偏離所報(bào)道的_diffrn_ambient_temperature值。
(http://journals.iucr.org/services/cif/checking/PLAT193.html)
警告原因:CIF中_cell_measurement_temperature和_diffrn_ambient_temperature相差較大。
解決策略:根據(jù)實(shí)際情況將其改正即可。
PLAT197 Type_1 Test for specification of unitcell measurement temperature
Please specify the temperature (Kelvin) at which the unit-cell was determined.
請(qǐng)指定單胞測定的溫度(開爾文)。
(http://journals.iucr.org/services/cif/checking/PLAT197.html)
警告原因:未給出晶胞測定的溫度。
解決策略:根據(jù)實(shí)際情況在CIF中_cell_measurement_temperature填上即可。
PLAT198 Type_1 Test for specification of Datacollection temperature
Please specify the temperature (Kelvin) at which the intensity data were collected.
請(qǐng)指定強(qiáng)度數(shù)據(jù)測定的溫度(開爾文)。
(http://journals.iucr.org/services/cif/checking/PLAT198.html)
警告原因:未給出強(qiáng)度數(shù)據(jù)測定的溫度。
解決策略:根據(jù)實(shí)際情況在CIF中_diffrn_ambient_temperature填上即可。
PLAT199 Type_1 Test for SHELXL Roomtemperature Default (Cell)
The cell determination temperature is set in the CIF by default by SHELXL97 to 293 K when the TEMP instruction is not used. The actual temperature is likely either slightly or significantly (in case of a low temperature data collection) different.
當(dāng)未使用TEMP命令時(shí),CIF中晶胞測定的溫度由SHELXL97設(shè)定為默認(rèn)值293K。實(shí)際溫度可能略有不同,也可能顯著不同(在低溫進(jìn)行數(shù)據(jù)收集的情況下)。
(http://journals.iucr.org/services/cif/checking/PLAT199.html)
警告原因:晶胞測定的溫度為SHELXL指定的室溫默認(rèn)值。
解決策略:檢查是否與實(shí)際情況相符,否則根據(jù)實(shí)際情況在CIF中_cell_measurement_temperature改正即可。
PLAT200 Type_1 Test for SHELXL Roomtemperature Default (Datacollection)
The data collection temperature is set in the CIF by default by SHELXL97 to 293 K if the TEMP instruction is not used. The actual temperature is likely either slightly or significantly (for a low temperature data collection) different.
當(dāng)未使用TEMP命令時(shí),CIF中數(shù)據(jù)收集的溫度由SHELXL97設(shè)定為默認(rèn)值293K。實(shí)際溫度可能略有不同,也可能顯著不同(在低溫進(jìn)行數(shù)據(jù)收集的情況下)。
(http://journals.iucr.org/services/cif/checking/PLAT200.html)
警告原因:數(shù)據(jù)收集的溫度為SHELXL指定的室溫默認(rèn)值。
解決策略:檢查是否與實(shí)際情況相符,否則根據(jù)實(shí)際情況在CIF中_diffrn_ambient_temperature改正即可。
PLAT201 Type_2 Test for isotropic non-H atoms in main residue(s)
This test reports on non-hydrogen atoms that were refined with isotropic displacement parameters only in the main residue. Such a practice is unusual by modern standards and only needed for minor disorder modelling.
(http://journals.iucr.org/services/cif/checking/PLAT201.html)
警告原因:部分非氫原子沒有進(jìn)行各向異性精修。
解決策略:將所有原子進(jìn)行各向異性精修并重新生成CIF文件,否則需要給出合理解釋。
PLAT202 Type_3 Test for isotropic non-H atoms in anion ? or solvent ?
This test reports on isotropically refined atoms in small moieties (usually anions or solvent).
此檢查報(bào)告小部分(通常為陰離子或溶劑)中各向同性精修的原子。
(http://journals.iucr.org/services/cif/checking/PLAT202.html)
警告原因:部分非氫原子沒有進(jìn)行各向異性精修。
解決策略:將所有原子進(jìn)行各向異性精修并重新生成CIF文件,否則需要給出合理解釋。
PLAT203 Type_2 Test for negative non-Hydrogen U(iso)
Isotropic U(iso) values are expected to have a positive value.
(http://journals.iucr.org/services/cif/checking/PLAT203.html)
例:PLAT203_ALERT_2_A Negative Isotropic ADP for O3 ........ -0.010 Report
警告原因:O3原子溫度因子為負(fù)值。
解決策略:如果僅是個(gè)別原子不正常,檢查原子類型是否定錯(cuò),是否需要無序處理,或采用delu或者isor限制精修;如果整體溫度因子不正常,檢查數(shù)據(jù)質(zhì)量是否足夠高,或者定錯(cuò)空間群。